PUMPS
Showing 1–12 of 16 resultsSorted by latest
-
PUMPS
Fire Fighting Pumps SDS UL/FM
Design Features According to UL & FM
All interior bolt or screw that are exposed to pumped liquid shall be of rolled bronze or corrosion resistant material
The pump shall be provided with automatic air-release valve, circulation relief valve and pressure gauges
Bearings shall have an L-10 rating of not less than 5000 hours at maximum load.
The pumps shall be provided with at least four packing rings plus a lantern ring. The lantern ring may be permitted to replace one ring of packing.
Impellers, wear rings, shafts, lantern rings, glands shall be made of corrosion resistant material.
Following material specifications are applied to STANDART UL/FM fire pumpsSKU: n/a -
PUMPS
Fire Fighting Pumps SNK UL/FM
Design Features According to UL & FM
All interior bolt or screw that are exposed to pumped liquid shall be of rolled bronze or corrosion resistant material
The pump shall be provided with automatic air-release valve, circulation relief valve and pressure gauges
Bearings shall have an L-10 rating of not less than 5000 hours at maximum load.
The pumps shall be provided with at least four packing rings plus a lantern ring. The lantern ring may be permitted to replace one ring of packing.
Impellers, wear rings, shafts, lantern rings, glands shall be made of corrosion resistant material.
Following material specifications are applied to STANDART UL/FM fire pumpsSKU: n/a -
PUMPS
Fire Fighting Pumps NFPA 20
Fire Pump Group Control System
Individual control panels are used for electric pump, diesel pump and jockey pump
Lock mechanism are used on panels
Continuous grounding
Pumps can run by manual control and emergency-run mechanical control on controller
By the help of Locked Rotor Protection (LRP), in case of locking rotor main switch is automatically shut down.
No thermic protection on controller (except jockey pump controller)
Alarm signals on electric pump controller (except jockey pump)
1. pump running
2. pump failure
3. minimum water level(if required)
4. phase reversal
5. loss of phase
6. power suitable
7. lamp test (if required)
8. audible(can be switched off) and visible(can not be switched off) alarms
9. LRP
Two 12 V batteries for diesel engine
Battery chargers
Additive alarm signals for diesel driven pumps
1. high motor temperature
2. low oil pressure
3. over speed
4. control is in automatic mode
5. charger lamp
6. failure of 1st battery
7. failure of 2nd battery
8. starting failure
9. failure of battery charger
10. engine running
11. lamp test button (optional)
12. audible(can be switched off) and visible(can not be switched off) alarmsSKU: n/a -
PUMPS
Booster TH GRV-VD / VB
General Information
High pressure, quiet running, compact and low power consumption. GRV-VD / VB pumps are suitable for pumping non-abrasive, clean or slightly contaminated, low viscosity without solid & fibrous particles liquids. Vertical structure saves space.
Technical Information
Capacity : up to 60 kW
Head : up to 170 m
Casing Pressure (Pmax) : 10 – 16 – 25 bar
Operating Temperature (°C) : up to +50 CSKU: n/a -
PUMPS
Booster TH SKMV
General Information
High pressure, quiet running, compact and low power consumption. SKMV pumps are suitable for pumping non-abrasive, clean or slightly contaminated, low viscosity without solid & fibrous particles liquids. Vertical structure saves space.
Technical Information
Capacity : up to 500 kW
Head : up to 180 m
Casing Pressure (Pmax) : 10 – 16 – 25 bar
Operating Temperature (°C) : up to +70 CSKU: n/a -
PUMPS
Booster TH SB
General Information
It is high pressure, quiet running, compact and low power consumption. SB pumps are suitable for pumping non-abrasive, clean or slighty contaminated, low viscosity liquids without solid & fibrous particles. Vertical structure saves space.
Technical Information
Flow : up to 15 m3/h
Head : up to 120 m
Casing Pressure (Pmax) : 10 – 16 bar
Operating Temperature (°C) : 0 C’ up to +50 CSKU: n/a -
PUMPS
Booster TH CDLF
General Information
High pressure, quiet running, compact and low power consumption. All surfaces that contact with the liquid are stainless steel, ln-line (straight pipe attachable) type pumps. CDLF pumps are suitable for pumping non-abrasive, clean or slightly contaminated, low-viscosity liquids without solid & fibrous particles. Bearing is provided by tungsten carbide sliding bearings. Vertical structure saves space.
Technical Information
Capacity : up to 110 kW
Head : up to 160 m
Casing Pressure (Pmax) : 10 – 16 – 25 bar
Operating Temperature (°C) : -10 C up to +120 CSKU: n/a -
PUMPS
Pumps SSP-V
Handled Liquids
Slurry, highly contaminated, viscous, corrosive and abrasive liquids with solid or fibrous particles.
SSP-V pump series are carefully designed by taking into consideration years of production experience of STANDART POMPA and field experiences of our customers using process and slurry pumps. Hydraulic efficiency and hardwearing are considerate and optimised while hard solid particles were pumping.
Technical Information
Discharge Flange : DN 50…DN 250 mm
Flow : up to 3500 m3/h
Head : up to 40 m
Operating Temperature (°C) : -10 C’ up to +110 CSKU: n/a -
PUMPS
Pumps SSP-H
Handled Liquids
SSP-H series HC model pumps are centrifugal pumps that have horizontal shaft, volute casing, single stage and closed impeller. Semi-open or vortex impeller types can be applied in different requirements.
Technical Information
Discharge Flange : DN 50…DN 350 mm
Flow : up to 3500 m3/h
Head : up to 100 m
Operating Temperature (°C) : -10 C’ up to +110 CSKU: n/a